competence

TECHNICAL TERMS

PRODUCT TYPE ABBREVIATIONS

Li: strand conductor construction
F: finest-strand construction
Y : plastic based on PVC
2Y : plastic based on PE
9Y : plastic based on PP
YW : national abbreviation for temperature-resistant plastic based on PVC
11Y: Kunststoff auf PUR-Basis
12Y: plastic based on TPE-E
30Y: thermoplasic natural rubber
31Y: temperature-resistant thermoplasic elastomer
32Y: special temperature-resistant thermoplasic elastomer
X: radial distributed PVC
2X: cross-linked polyehylene
11X: radial distributed PUR
SK: suitable for dragchains
FRNC: flame retardant and halogen-free wire
-J: including green-yellow ground wire
-O: without green-yellow ground wire
-B: coloured wires
-Z : number print
-C: screening meshwork

 general harmonised abbreviations:

H: harmonised wires
S: special wires
03: nominal voltage Uo/U 300/300 V
05: nominal voltage Uo/U 300/500 V
07: nominal voltage Uo/U 450/470 V
V: PVC based wire insulation
V: PVC based sheath material
V2: harmonised abbreviation for temperature-resistant PVC (+ 90° C)
-F: finely-wired construction of bunched conductors according to DIN VDE 0281
3G: twisted wire with three wires and green-yellow ground wire
0,75: 0,75 mm² conductor cross section

TYPE ABBREVIATION OF AUTOMOTIVE WIRES

wire type

FL: automotive wire, low voltage
FZL: automotive wire, high voltage, (ignition line)

 

application of used insulation and sheath material

Y: PVC, polyvinyl chloride

 

type of used shielding material

B: foil shield with ground wire
D: copper-based single wire shield
C: copper screen

 

non-extruded sheaths

G: fibre glass mesh
T: textile weave

 

special construction features

R: 4 reduced insulation thickness according to DIN ISO 6722, Part 4
U: ultra reduced insulation thickness
S: insulation thickness bigger than according to DIN ISO 6722, Part 3
F: non-seperable flat wire
Z: multiple core, non-separable wire
M: other conductor materials than E-Cu or resistance alloies
W: resistance conductor

number of wires and conductor cross section

0,5: conductor cross section 0,5 mm²
0,5 sn: conductor cross section 0,5 mm², tinned
3 x 0,5: three wires with conductor cross section 0,5 mm² each
W/km: on resistance conductors information in Ohm/km

&nb

examples:
FLRY 2,50 mm² verz: FL = automotive wire

  R = with reduced insulation thickness

  Y = PVC insulation
  2,50 mm² verz = conductor cross section 2,50 mm² tinned

FL11Y 16,00 mm² blk: FL = automotive wire

  11Y = PUR sheath
  16,00 mm² blk = conductor cross section 16,00 mm² bare
FLRYY 3 x 0,25 mm² blk: FL = automotive wire
  R = with reduced insulation thickness
  Y = wire insulation PVC based

  Y = sheath insulation PVC based

  3 x 0,25 mm² blk = three single wires with cross conductor section 0,25 mm² each, bare

 